Range and Scientific MWIR Camera

FLIR RS6780

Go to Product Support
product image

The FLIR RS6780 offers advanced detector, triggering, and synchronization capabilities in an environmentally protected package, making it easy to configure and integrate for successful data acquisition in the most demanding R&D applications. With a three-position motorized filter wheel and continuous metric zoom (CZ) lens, the RS6780 records sharply focused, high-quality thermal images in long-range and tracking applications. The standard 50-250 mm CZ lens can be factory-calibrated for temperature and radiance measurements, allowing researchers to use the radiometric camera system without sacrificing the flexibility of the optics platform.

Sales Contact Contact Sales

  • Superior measurement accuracy

    Capture crisp thermal images of high-temperature targets with 640 x 512 resolution, a three-position filter wheel, and continuous metric zoom lens

  • Flexible

    Synchronize the camera with external events or instrumentation, control precisely when an image frame is generated with advanced triggering, and embed TSPI-accurate data timestamping

  • Small and rugged

    Easily integrate this lightweight system indoors or outdoors – the IP65 weatherproof enclosure provides protection in the harshest environments

FLIR Research Studio Streaming, Recording, and Analysis Software

FLIR Research Studio Streaming, Recording, and Analysis Software

Stream thermal data directly to a computer to view, record, and analyze with FLIR Research Studio software

Contact Sales

Want more information on this product?

Call +1 (866) 477-3687 to speak with a knowledgeable specialist.

Specifications
Resolution
640 × 512
Detector Pitch
15 µm
Spectral Range
3.0 – 5.0 µm
Detector Type
FLIR indium antimonide (InSb)
Camera f-number
f/4.0
Dynamic Range
14-bit
Frame Rate [Full Window]
Programmable 0.0015 Hz to 125 Hz
Integration Time
480 ns to ~full frame
Standard Temperature Range
0°C to 350°C (32°F to 662°F)
Optional Temperature Range
Using ND filters up to 3000°C
Focus
Motorized FOV/focus
Imaging & Optical
Camera f-number
f/4.0
Detector Pitch
15 µm
Detector Type
FLIR indium antimonide (InSb)
Digital Zoom
1x, Auto (best fit), off
Dynamic Range
14-bit
Focus
Motorized FOV/focus
Frame Rate [Full Window]
Programmable 0.0015 Hz to 125 Hz
Image Time Stamp
Internal precision timestamp, IRIG-B AM decoder, TSPI accurate
Integration Time
480 ns to ~full frame
Lens
50-250 mm continuous metric zoom - low latency metadata (with 3x afocal optional attachment - 150-750 mm)
Lens Cover
Optional, motorized
On Camera Image Storage
None
Operability
≥99.95% typical
Overlay
Customizable (ability to toggle off)
Palette
Selectable 8-bit
Pixel Clock
50 MHz
Radiometric Data Streaming
Gigabit Ethernet (GigE Vision), CoaXPress Single Link 1.1
Readout Modes
Asynchronous integrate while read, asynchronous integrate then read
Readout Type
Snapshot
Resolution
640 × 512
Sensor Cooling
Closed-cycle rotary
Spectral Range
3.0 – 5.0 µm
Standard Video
SDI
Subwindow Modes
Flexible windowing down to 16 × 4 (steps of 16 columns, 4 rows)
Thermal Sensitivity_NETD [typical]
27 mK typical
Video Modes
SDI: 720p@50/59.9, 1080p@25/29.9, 480i@60 Hz, 576i@50 Hz
Measurement & Analysis
Accuracy
≤100°C ±2°C (±1°C typical), >100°C ±2% of reading (±1% typical)
Ambient Drift Compensation [with factory cal]
Yes
Automatic Gain Control
Manual, Linear, Plateau equalization, DDE
Optional Temperature Range
Using ND filters up to 3000°C
Standard Temperature Range
0°C to 350°C (32°F to 662°F)
Communication & Data Storage
Command and Control
GigE, CoaXPress (GenICam protocol supported over GigE or CXP), RS-232
Synchronization Modes
Sync In, Sync Out, Tri-Level Sync, IRIG, Lock-In
Trigger Mode(s)
Trigger in, header based
General
Size (L x W x H)
544 mm × 177.8 mm × 213.9 mm (21.43 in × 7 in × 8.42 in) - (w/o 3x); 726.44 mm × 243.38 mm × 240.74 mm (28.6 in × 9.582 in × 9.478 in) - (w/3x)
Weight
Without 3x afocal - 12.7 kg (28 lb), With 3x afocal - 16.78 kg (37 lb)
Power
Power
24 VDC (<24 W steady state)
Environmental & Certifications
IP Rating
IP65
Mounting
5 × ¼" -20 tapped holes, 2x 3/8" -16 tapped holes
Operating Temperature Range
-20°C to 50°C (-4°F to 122°F)
Media gallery
Range & Scientific Thermal Camera for Commercial Applications
Range &amp; Scientific Thermal Camera for Commercial Applications
Flexible Range and Scientific Thermal Camera for Defense Research Applications
Flexible Range and Scientific Thermal Camera for Defense Research Applications
Related Documents
Export Restrictions

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.

FLIR RS6780